Multicast features |
---|
Multicast support | Yes |
Certificates |
---|
Certification | FCC 47 CFR Part 15 subpart B Class A, EN 55032/CISPR 32 Class A, VCCI Class A, AS/NZS CISPR 32 Class A, CISPR 11 Class A, ICES 003 Class A, CNS 13438 Class A, KN 32 Class A, EN 300 386, CISPR 24, EN 55024, KN 35, EN 61000-4-2 Electro Static Discharge (air – 15kV, contact – 8kV), EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP), EN 61000-4-4 Electromagnetic Fast Transients (4kV), EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP), EN 61000-4-6 Conducted RF (10Vrms UTP), EN 61000-4-8 Power Frequency Magnetic Field (1000A/m), EN 61000-4-10 Pulsed Magnetic Field (30 A/m), EN 61000-4-16 Conducted CM Disturbances (30V, Cont/ 300V, 1 sec), EN 61000-4-17 Ripple Immunity DC Power (10%), EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz), EN-61000-4-29 DC Voltage Dips and Interruptions, EN 61000-6-2 Industrial Immunity, EN 61000-6-4 Industrial Emissions, EN 61000-6-1 Light Industrial Immunity, EN 61326-1 Measurement, Control and Laboratory Equipment, IEEE 1613 Electric Power Stations Communications Networking2, EN/IEC 61850 -3 Electric Substations Communications Networking2, EN50121-4 Railway – Signaling and Telecommunications Apparatus, ODVA Industrial EtherNet/IP, IP30, Information Technology Equipment:, UL/CSA 60950-1, CB to IEC 60950-1 with all country deviations, UL/CSA 62368-1, CB to IEC 62368-1 with all country deviations2, Industrial floor (control equipment):, UL/CSA 61010-2-201, CB report and certificate to IEC/EN 61010-2-201, Hazardous Locations, UL121201(Class l, Div 2, groups A-D), CSA 213 (Class l, Div 2, groups A-D), UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC), IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC), EN 60079-0, -15 ATEX certifícate (Class l, Zone 2, Gc/IIC) cabinet enclosure required, IEC 60068-2-14, IEC 60068-2-78, IEC 60068-2-30, IEC 60068-2-27, IEC 60068-2-52, IEC 60068-2-60 |
Memory |
---|
Internal memory | 4000 MB |
Flash memory | 1500 MB |
Design |
---|
International Protection (IP) code | IP20 |
DIN rail mounting | Yes |
Product colour | Black |
Certification | FCC 47 CFR Part 15 subpart B Class A, EN 55032/CISPR 32 Class A, VCCI Class A, AS/NZS CISPR 32 Class A, CISPR 11 Class A, ICES 003 Class A, CNS 13438 Class A, KN 32 Class A, EN 300 386, CISPR 24, EN 55024, KN 35, EN 61000-4-2 Electro Static Discharge (air – 15kV, contact – 8kV), EN 61000-4-3 Radiated RF (10V/m UTP, 20V/m STP), EN 61000-4-4 Electromagnetic Fast Transients (4kV), EN 61000-4-5 Surge (2KV/1KV Power, 4KV STP), EN 61000-4-6 Conducted RF (10Vrms UTP), EN 61000-4-8 Power Frequency Magnetic Field (1000A/m), EN 61000-4-10 Pulsed Magnetic Field (30 A/m), EN 61000-4-16 Conducted CM Disturbances (30V, Cont/ 300V, 1 sec), EN 61000-4-17 Ripple Immunity DC Power (10%), EN 61000-4-18 Damped Oscillatory Wave (2.5kV, 1MHz), EN-61000-4-29 DC Voltage Dips and Interruptions, EN 61000-6-2 Industrial Immunity, EN 61000-6-4 Industrial Emissions, EN 61000-6-1 Light Industrial Immunity, EN 61326-1 Measurement, Control and Laboratory Equipment, IEEE 1613 Electric Power Stations Communications Networking2, EN/IEC 61850 -3 Electric Substations Communications Networking2, EN50121-4 Railway – Signaling and Telecommunications Apparatus, ODVA Industrial EtherNet/IP, IP30, Information Technology Equipment:, UL/CSA 60950-1, CB to IEC 60950-1 with all country deviations, UL/CSA 62368-1, CB to IEC 62368-1 with all country deviations2, Industrial floor (control equipment):, UL/CSA 61010-2-201, CB report and certificate to IEC/EN 61010-2-201, Hazardous Locations, UL121201(Class l, Div 2, groups A-D), CSA 213 (Class l, Div 2, groups A-D), UL/CSA 60079-0, -15 (Class l, Zone 2, Gc/IIC), IEC 60079-0, -15 IECEx test report (Class l, Zone 2, Gc/IIC), EN 60079-0, -15 ATEX certifícate (Class l, Zone 2, Gc/IIC) cabinet enclosure required, IEC 60068-2-14, IEC 60068-2-78, IEC 60068-2-30, IEC 60068-2-27, IEC 60068-2-52, IEC 60068-2-60 |
Rack mounting | Yes |
Performance |
---|
Mean time between failures (MTBF) | 549808 h |
Internal memory | 4000 MB |
Flash memory | 1500 MB |
Harmonized System (HS) code | 85176990 |
Power |
---|
Power consumption (typical) | 36 W |
Input current | 6.3 A |
DC input voltage | 9.6 - 60 V |
Power over Ethernet (PoE) |
---|
Power over Ethernet (PoE) | No |
Operational conditions |
---|
Storage temperature (T-T) | -40 - 85 °C |
Operating temperature (T-T) | -40 - 70 °C |
Operating relative humidity (H-H) | 5 - 95% |
Non-operating altitude | 0 - 4572 m |
Weight & dimensions |
---|
Width | 152.4 mm |
Depth | 134.6 mm |
Height | 91.4 mm |
Weight | 1.72 kg |
Logistics data |
---|