Description
|
Cable for 1U 12 x 2.5” system (M50CYP1UR212) to support PCIe NVMe drives in front drive bay
Included Items: 1 x 412/420 mm splitter cable, connects server board CPU0 x4 SlimSAS A and B connectors (RRA) to HSBP x8 SlimSAS SSD0-1 connector (VT) 1 x 400/392 mm splitter cable, connects server board CPU1 x4 SlimSAS C and D connectors (RRA) to HSBP x8 SlimSAS SSD10-11 connector (VT) 1 x 350/342 mm splitter cable, connects server board CPU0 x4 SlimSAS C and D connectors (RRA) to HSBP x8 SlimSAS SSD2-3 connector (VT) 1 x 312/320 mm splitter cable, connects server board CPU1 x4 SlimSAS A and B connectors (RRA) to HSBP x8 SlimSAS SSD8-9 connector (VT)
|
2U 8 port Switch accessory cable kit, Riser 1 or Riser 2 (2 cables included). Contains the following OCuLink bundled cables:
- 875mm long, bundled cable kit (2 cables included) straight OCuLink SFF-8611 connectors to straight/right angle OCuLink SFF-8611 connectors.
Used in the R2208+8 and R2224 to connect switch AIC installed in Riser 2 to HSBP PCIe SSD ports 0 -7.
|
2U 8 port Switch accessory cable kit, Riser 1 or Riser 2 (2 cables included). Contains the following OCuLink bundled cables:
- 725mm long, bundled cable kit (2 cables included) straight OCuLink SFF-8611 connectors to straight/right angle OCuLink SFF-8611 connectors.
Used in the R2208, R2208+8 and R2224 to connect switch AICs to HSBP PCIe SSD ports (SSD ports depend on installed location of the switch AIC).
|
Cables tested and approved to ensure a successfully deployed storage solution.
- Various internal cable options ease system integration - Cables are thoroughly tested to deliver quality and performance
|
Cables tested and approved to ensure a successfully deployed storage solution.
- Various internal cable options ease system integration - Cables are thoroughly tested to deliver quality and performance
|
Cable for 2U M50CYP2UR x16 front drive bay system to enable PCIe NVMe storage.
Included Items: 1 x 275/255 mm splitter cable, connects server board CPU0 x4 SlimSAS C and D (VT) to HSBP (left) x8 SlimSAS SSD6-7 (VT) 1 x 305/325 mm splitter cable, connecting server board CPU0 x4 SlimSAS A and B (VT) to HSBP (left) x8 SlimSAS SSD4-5 (VT) 1 x 360/340 mm splitter cable, connects server board CPU1 x4 SlimSAS A and B (VT) to HSBP (right) x8 SlimSAS SSD14-15 (VT) 1 x 240/260 mm splitter cable, connects server board CPU1 x4 SlimSAS A and B (VT) to HSBP (right) x8 SlimSAS SSD12-13 (VT)
|
Short Description
|
1U SlimSAS Cable x12
|
Oculink Cable Kit A2U8PSWCXCXK2
|
Oculink Cable Kit A2U8PSWCXCXK1
|
1m, x8 SFF-8654, 2 x4 SFF-8612 (OCuLink)
|
1m, x8 SFF-8654, x8 SFF-8654 (SlimSAS)
|
2U SlimSAS Cable x16
|