My Cart
You have no items in your shopping cart.
SKU | CYPCBLSL216KIT |
---|---|
EAN | 5032037213103 |
Manufacturer | Intel |
Availability | In Stock |
Product |
![]() Hot Product
Intel CYPCBLSL216KIT Serial Attached S...
£96.61
£80.51
|
![]() Popular
Intel A2U8PSWCXCXK2 Serial Attached SC...
£128.81
£107.34
|
![]() Recommended
Intel A2U8PSWCXCXK1 Serial Attached SC...
£123.44
£102.87
|
![]() Bestseller
Broadcom 05-60001-00 Serial Attached S...
£92.21
£76.84
|
![]()
£79.61
£66.34
|
![]() New
Intel CYPCBLSL208KIT Serial Attached S...
£109.49
£91.24
|
---|---|---|---|---|---|---|
SKU |
CYPCBLSL216KIT
|
A2U8PSWCXCXK2
|
A2U8PSWCXCXK1
|
05-60001-00
|
05-60007-00
|
CYPCBLSL208KIT
|
Description |
Cable for 2U M50CYP2UR x16 front drive bay system to enable PCIe NVMe storage.
Included Items: 1 x 275/255 mm splitter cable, connects server board CPU0 x4 SlimSAS C and D (VT) to HSBP (left) x8 SlimSAS SSD6-7 (VT) 1 x 305/325 mm splitter cable, connecting server board CPU0 x4 SlimSAS A and B (VT) to HSBP (left) x8 SlimSAS SSD4-5 (VT) 1 x 360/340 mm splitter cable, connects server board CPU1 x4 SlimSAS A and B (VT) to HSBP (right) x8 SlimSAS SSD14-15 (VT) 1 x 240/260 mm splitter cable, connects server board CPU1 x4 SlimSAS A and B (VT) to HSBP (right) x8 SlimSAS SSD12-13 (VT) |
2U 8 port Switch accessory cable kit, Riser 1 or Riser 2 (2 cables included). Contains the following OCuLink bundled cables:
- 875mm long, bundled cable kit (2 cables included) straight OCuLink SFF-8611 connectors to straight/right angle OCuLink SFF-8611 connectors. Used in the R2208+8 and R2224 to connect switch AIC installed in Riser 2 to HSBP PCIe SSD ports 0 -7. |
2U 8 port Switch accessory cable kit, Riser 1 or Riser 2 (2 cables included). Contains the following OCuLink bundled cables:
- 725mm long, bundled cable kit (2 cables included) straight OCuLink SFF-8611 connectors to straight/right angle OCuLink SFF-8611 connectors. Used in the R2208, R2208+8 and R2224 to connect switch AICs to HSBP PCIe SSD ports (SSD ports depend on installed location of the switch AIC). |
Cables tested and approved to ensure a successfully deployed storage solution.
- Various internal cable options ease system integration - Cables are thoroughly tested to deliver quality and performance |
Cables tested and approved to ensure a successfully deployed storage solution.
- Various internal cable options ease system integration - Cables are thoroughly tested to deliver quality and performance |
Cable for 2U M50CYP2UR208 system to enable PCIe NVMe storage. (1) 240/260 mm splitter cable, connects server board CPU0 x4 SlimSAS A and B (VT) to HSBP x8 SlimSAS SSD0-1 (VT) (1) 330/310 mm splitter cable, connects server board CPU0 x4 SlimSAS C and D (VT) to HSBP x8 SlimSAS SSD2-3 (VT) (1) 235/215 mm splitter cable, connects server board CPU1 x4 SlimSAS C and D (VT) to HSBP x8 SlimSAS SSD6-7 (VT) (1) 370/390 mm splitter cable, connects server board CPU1 x4 SlimSAS A and B (VT) to HSBP x8 SlimSAS SSD4-5 (VT)
|
Short Description |
2U SlimSAS Cable x16
|
Oculink Cable Kit A2U8PSWCXCXK2
|
Oculink Cable Kit A2U8PSWCXCXK1
|
1m, x8 SFF-8654, 2 x4 SFF-8612 (OCuLink)
|
1m, x8 SFF-8654, x8 SFF-8654 (SlimSAS)
|
2U SlimSAS Cable x8 (CPU to HSBP Kit CYPCBLSL208KIT)
|
Manufacturer |
Intel
|
Intel
|
Intel
|
Broadcom
|
Broadcom
|
Intel
|